Tools
Instructions
Furnace
Vickers Hardness Tester
Aluminium Alloy Sample
Step 1: Placing of the Furnace
Drag the Furnace from the tools.
Right click on the furnace and click on pin.
Step 2: Heating of the sample in the Furnace.
Right click on the sample and drag it close to the furnace.
Now,place the sample on the machine & click on pin.
Keep all the solutionized samples in the furnace for aging at 120 deg C
You can adjust zoom level also (Via Mouse Wheel).
Step 3: Hardness Testing of the sample in Vickers.
Right click on the chamber of Furnace presented in the middle to unload the sample.
Now,place the sample on the Vickers & click on pin.
You can adjust zoom level also (Via Mouse Wheel).
Step 4: Observation Of Indent impressions of Al alloy age hardened at different durations .
Time (in hrs)
Indent Impressions
Perform d1 & d2 measurement from indent impressions of Al alloy.
Step 5: Plot the graph.
Click below buttons to start the machine.
Test1 for 466.8 gf load at 120 deg C
Start Test
Time in hrs
Hardness (HV)
Step 6: Results
Aging curve of aluminum alloy at 120℃
Peak-hardness = 177 HV
Step 7: Activity.
Click next button to continue.
Next